Setting up your Ontech GSM 9025, 9035 or 9050 Unit
To set new settings or change old settings you must follow these steps:
Hints
Most common settings (temperature alarms, delays, control relay and power fail)
Password - must be filled in |
Must be filled in with your password. Four digits. |
|
Air pump (Only for model Ontech 9050) | ||
Select air pump |
Select your type of air pump. To use this function, you need Ontech 9050, i.e. Ontech 9040 Master with the 'IR eye' (Ontech 9016). |
|
Temperature settings (Master) | ||
Select active sensor |
Select the sensor that shall be used for temperature alarms and for the thermostat function. |
|
Temperature below alarm (-30° to +60°C) |
An alarm SMS will be sent if the temperature drops below the set temperature. The temperature alarm will be automatically acknowledged when the temperature rises above the selected temperature. It is not possible to manually acknowledge this alarm. Clear the input field to disable this alarm. |
|
Temperature above alarm (-30° to +60°C) |
An alarm SMS will be sent if the temperature rises above the set temperature. The temperature alarm will be automatically acknowledged when the temperature drops below the selected temperature. It is not possible to manually acknowledge this alarm. Clear the input field to disable this alarm. |
|
Delay alarm (Master) | ||
Alarm delay settings |
Set the time (in seconds) from the sensor is activated until an alarm SMS is sent. This setting only applies to wired sensors connected to the master. See the Advanced Settings tab for changing the alarm delay for any wireless Ontech units. |
|
Auto relay settings (Master) | ||
Auto relay |
Select if you want the relay on the master to get activated/deactivated in the case of an alarm. |
|
Alarm input settings (Master) | ||
Alarm inputs |
Both NC (Normally Closed) and NO (Normally Open) alarm sensors can be used with the system. Select the type you have connected by wire to the master unit. |
|
Power fail setting | ||
Power fail |
Set the time (in minutes) from the unit detects a power failure until it sends an SMS. |
Help
Fill in up to nine different receivers of SMS alarms from the unit
Password - must be filled in | ||
SMS Alarm numbers | ||
Alarm number 1 |
If this is set to a mobile number, an alarm SMS will be sent to this number every time an alarm is generated. |
|
Alarm number 2 | ||
Alarm number 3 | ||
Alarm number 4 | ||
Alarm number 5 | ||
Alarm number 6 | ||
Alarm number 7 | ||
Alarm number 8 | ||
Alarm number 9 |
Help
Advanced settings (radio channel, slave settings, units for timer, battery messages, alarm blink, status messages, sensor settings)
Password - must be filled in | ||
Radio settings | ||
Radio |
The radio can be set to OFF if you do not have any extra units. It will also reduce the power consumption. |
|
Radio Channel |
There is no need to change the channel unless you experiance communication problems with Ontech units. If the channel is changed, it must also be changed on all units. |
|
Temperature and alarm delay for 9012 and 9015 (Unit 2) | ||
Select active sensor |
Select the sensor that shall be used for temperature alarms and for the thermostat function. External sensor can only be used with Ontech 9015 units. |
|
Temperature below alarm (-30° to +60°C) |
||
Temperature above alarm (-30° to +60°C) |
||
Alarm delay |
Set the time (in seconds) from the sensor is activated until an alarm SMS is sent. This setting applies to wired sensors connected to the unit. |
|
Temperature and alarm delay for 9012 and 9015 (Unit 3) | ||
Select active sensor | ||
Temperature below alarm (-30° to +60°C) |
||
Temperature above alarm (-30° to +60°C) |
||
Alarm delay | ||
Temperature and alarm delay for 9012 and 9015 (Unit 4) | ||
Select active sensor | ||
Temperature below alarm (-30° to +60°C) |
||
Temperature above alarm (-30° to +60°C) |
||
Alarm delay | ||
Temperature and alarm delay for 9012 and 9015 (Unit 5) | ||
Select active sensor | ||
Temperature below alarm (-30° to +60°C) |
||
Temperature above alarm (-30° to +60°C) |
||
Alarm delay | ||
Temperature and alarm delay for 9012 and 9015 (Unit 6) | ||
Select active sensor | ||
Temperature below alarm (-30° to +60°C) |
||
Temperature above alarm (-30° to +60°C) |
||
Alarm delay | ||
Temperature and alarm delay for 9012 and 9015 (Unit 7) | ||
Select active sensor | ||
Temperature below alarm (-30° to +60°C) |
||
Temperature above alarm (-30° to +60°C) |
||
Alarm delay | ||
Temperature and alarm delay for 9012 and 9015 (Unit 8) | ||
Select active sensor | ||
Temperature below alarm (-30° to +60°C) |
||
Temperature above alarm (-30° to +60°C) |
||
Alarm delay | ||
Other settings | ||
Unit for timer |
When a relay is set for a specific time, this setting defines if the time should be counted in seconds, minutes or hours. |
|
Battery messages |
If this setting is OFF, no "low battery" message will be sent (only Ontech GSM 9025). |
|
Status |
If this is set to a phone number, all status and update requests will be sent to this number instead of the mobile phone that sent the original request. |
|
GPS Fence |
Only for Ontech GSM 9025: If you have a GPS connected, this will set the allowed size of the GPS Fence function. |
|
24 Volt |
Select ON if the master is powered by 24V. This setting only affects at which battery level the "battery low"-SMS will be sent (only Ontech GSM 9025). |
|
Alarm blink |
If this setting is OFF, the red LED will never blink when there is an alarm. |
|
Server mode (for version R40 or later) |
Server mode only works for the master relay. It means: 1. Relay is always ON after power failure. 2. It is not possible to control the relay with the button. 3. It is not possible to control the relay with SMS, except that the Relay timer function will still work. With Relay timer it is possible to turn the relay OFF for a specific number of seconds (or minutes). This is useful to restart the server. 4. Alarm will always be activated and is not possible to deactivate with SMS. |
|
Sensor (4-20mA) settings | ||
Sensor |
If this is active, you can connect a 4-20 mA sensor to the third pin of the temperature sensor connector. The 4-20 mA signal will be converted to a value between 0% and 100%. It also is possible to connect a 0-10V sensor to this pin. ON (no SMS) means you will not get any SMS when no current is detected. Contact us for more information (www.ontechgsm.com). |
|
Alarm level under |
An SMS will be sent every time the 4-20 mA sensor goes under this level. |
|
Alarm level over |
An SMS will be sent every time the 4-20 mA sensor goes over this level. |
Help
Garage opener
The garage opener feature makes it possible to program up to three phone numbers (position 1 to 3).
When any programmed number calls the GSM unit, it will directly hang up the call and give a pulse (activate the relay) for one second. This pulse can be used to control a garage opener motor.
Password - must be filled in | ||
Garage opener | ||
Function |
You can:
|
|
Position |
Select the position (1 to 3), where you want to store (or delete) the phone number. |
|
Phone number |
Enter the phone number that you want to program. |